Step 1 Inspect the power cord if the motor won't start. Check the heat exchanger If youre getting a lot of black soot coming out of your vent, its possible that there is too much carbon buildup on your heat exchanger, and it needs to be replaced before any more problems occur. Now, turn ON your flame source and place the tip of the thermocouple in the flame, leaving it until its very hot. Gas heater. Inspect your wiring thoroughly, make sure the connections are secure. However, there is little you can do with a heater thats smoking or blowing smoke out of the vent besides replacing it. Check the following parts of your propane system for damage. You must log in or register to reply here. Heat is applied to an electrical surface, which ignites the fuel. Particularly the tank, lines, pump, etc. Your concern about the Reddy heater might be solved once you get the problem. A firm must be made between the photocell and the lighting circuit. Follow the guides above the video and fix it. However, it may also be a severe issue, such as low gas supply caused by gas leaks. Fixing a Ventless Gas Heater that. A damaged thermocouple may also have pinholes. You should get a reading between 20mv and 30mv (millivolts). Heres what you can do to solve this issue: Low-quality kerosene will block the orifices and leave enormous amounts of debris in the burners, which might clog them. You know the name of the company for sure. You are using an out of date browser. it is one of the most common things to go bad on the reddy heater. It stays ON for as long as the furnace is ON, keeping an eye on the flame, and will cut the gas supply when it detects that the flame is gone. Make sure you know what each part is called and what it does. The burning of low-grade fuel or polluted oil may also produce smells and extra smoke. First of all, ensure that your Reddy heater is unplugged from power before starting work on it. http://www.msservice.net/desa/reddy-lp.html. We hope it will turn & rotate now. It will start up and run for about 30 second . Weve put together this list of causes and their easy solution in this Reddy heater troubleshooting guide for you. JavaScript is disabled. If you find damage, cracks, splits, or leaks in any parts of the fuel delivery system on your propane heater, replace them immediately. Fuel filter 2. Items 1-12 of 124. Unplug the unit and inspect the spark plug if the heater tries and fails to ignite. I was able to return the one I bought for another that did work. Circuit boards are great, but anything with moving parts will eventually wear down over time, even if its only used on the weekends or once a month. I have a kerosene burning 55000 btu ready heater. The air pressure in the system is critical for proper torpedo operation. Fixing pilot issue on a Ventless Gas Heater. Check to make sure the cord is plugged in and that the outlet has power. Generally, this type of problem may happen due to dirty or bad photocell. Another way to bypass photocells problems is by using a manual override. To fix this problem, you should replace/clean your air filter. If no change in resistance is seen during the test, replace it. Turn off the gas supply at the gas valve to prevent poisoning and avert potential fires. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. As an ignition source, the ignitor systems will produce a small electric spark. JavaScript is disabled. They serve as a safeguard against mishaps or the breakdown of other control systems. They can save you money by not having to use electricity or gas. A weak flame due to dirt buildup may not envelop the thermocouple completely, causing the flame sensor to return a negative answer. You can usually restart the heater after it cools down. The thermocouple may also be faulty, in which case it must be replaced. If you detect smoke or an odor from the heater despite attempting to light it and/or see no flame present, replace the entire fuel nozzle. Regular maintenance of your torpedo heater can help prevent many of these types of problems. Blocked Pilot Tube 7. It tells the proper pressure and where to check it in the owners manual. Faulty Thermostat: Your thermostat regulates the temperature of your heating system completely. Remove the dark supply tube from the nipple of the filter assembly. I just checked all my resets and everything check to make sure it was getting fuel read more. Make sure the transformers connections are secure at both ends. They have varied durability, yet they appear and fit the same. Reddy Heater Troubleshooting and Repair Part 1 - YouTube 0:00 / 19:13 Reddy Heater Troubleshooting and Repair Part 1 Farmboy's Garage 4.94K subscribers Subscribe 47K views 3 years ago Trying. 6 years college 17,128 satisfied customers Show more Cleaning a reddy heater is not so tough. Save my name, email, and website in this browser for the next time I comment. Use top graded fuel and clean the heater regularly to stop the bad smells from your heater. When the work meets the weather, Reddy Heater cuts through to comfort. Discontinue use and replace the fan if the shaft appears bent or damaged. On job sites, this can be an important safety feature. The heater uses a fan to pull air through a long tube, much like in a jet engine. First, check that the heater is plugged in and switched on (if it has a switch). If your torpedo heater has a pilot light, it should be visible near the orifice of the fuel delivery system. First, examine your thermostat's wires to ensure everything is plugged in correctly. The first thing I suggest is inspecting the power cord and ensuring it has not been damaged or compromised in any way (i.e., frayed cords). Ft. Displaced Thermocouple Heated End 4. Adjusting the photocell location is a simple way to solve this problem. We hope you have got the solution to your reddy heater starts then shuts off the issue. The most common cause of problems with these heaters is that that rubber or plastic fuel and air hoses stretch/swell where they push over the hose barbs. COPYRIGHT 2023. Also, make sure the connections from the circuit board and the photocell are disconnected. If anything looks like it might be leaking, tighten all connections (if you find something leaking after tightening everything, call Reddy customer support). Here well discuss how to bypass them if needed: Photocells can be bypassed by removing them from the circuit board. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fireplacehubs_com-leader-2','ezslot_15',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-leader-2-0');Now that you know all the common reasons that can be why your Reddy heater keeps shutting off, hopefully, you can get your heater started in no time. It may be removed by blowing it out with compressed air or washing it with a disinfectant. Check that the heater is not turned off at a circuit breaker. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Reddy Heater Won't Stay Running [7 Reasons To Fix] 1. If the motor runs but the heater does not light, or if you see smoke or detect a foul odor coming from the heater, check for fuel problems. The basic operation is the same across most torpedo heaters. Here are some tips on how to troubleshoot the problem quickly before getting rid of it: If youre experiencing issues with your Reddy heater not getting fuel, here are some things to check before calling a technician. (80 degrees for heating and 60 degrees for cooling). Additionally, the dirt in the fuel filter has the potential to damage the power switch wires. Unplug the unit, and then inspect the air passage of the fan. Move the thermocouple closer to the flame if necessary. Follow the manufacturers guidelines about using your torpedo heater and performing routine maintenance. 2023 householdair. Functioning Error Of Photocells 6. Unplug heater when not in use. Step 2: Switch off the appliance and remove the plug. Hunker may earn compensation through affiliate links in this story. Several other vital parts of the fuel delivery system on a propane-fired heater need maintenance and inspection as well. Air Conditioner Repair Near Dallas: How to Find the Best Company? The control board is essentially a computer. However, we recommend the following three-step process. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Finally, remove the wick and let it dry. The fan will not run if the air temperature in the room doesnt call for it to do so. When the light source is turned off by placing your hand over the photocells opening, the meters resistance should be high. Photocell Assembly Not Properly Installed 5. For every portable heating system, these are critical safety items. If temperatures inside the torpedo heater reach a pre-set level, the overheat sensor will shut it off.If the unit is accidentally tilted or falls over, the anti-tilt safeguard shuts off the fuel and the heater. I dont remember. Lind of disappointed as you show a picture of my 30-55K BTU propane heater then show me a fuel oil heater video. If you find air leaks around the draft hood of your burner assembly, this may mean the gasket is faulty and should be replaced with a new one to correct this problem. Some of the most common causes include: Reddy heaters are known for producing high energy output, even when they arent operating at full capacity. 2023 householdair. We will always be there for you when you need help. TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. If everything looks fine with these parts, take out one wire until you find which one isnt working correctly. Light the kerosene heater with little kerosene in the fuel tank. Locate the screw holding in the nozzle of your heater, and remove it with a wrench or pair of pliers. If the spark plug is rusted or damaged, replace it. Check to detect whether the filter is jammed with dirt or particles. Another cause of a weak pilot is a faulty. Where can I find a user manual for my kerosene heater? Here we have sorted out the reasons behind stopping the reddy heater and given their solution keenly. Stop using it and replace the fan if the shaft appears bent or damaged. Learn more, Facebook II Twitter II Pinterest II Linkedin. Answered on Dec 08, 2020 . net is your source for Information and Replacment parts for your Reddy Heater manufactured by DESA International prior to 2009. You should disassemble your heater to examine whether you placed the photocell assembly correctly or not. Follow the steps below to replace or clean the filter. Fixing a bad gas regulator is best left to the experts. These appliances will often operate without problem for many years if they are maintained well and operated correctly. Through sometimes, the heater may start initially without difficulties, it will automatically stop in a short time. The first lead wire goes to the thermocouple side, while the other goes to the part that typically goes into the pilot light. 508 satisfied customers. Modern View Forum powered by phpBB 2001, 2005 phpBB Group. Now you can turn back the multimeter to volts. If that doesn't work, you may need to call a repairman to come and install a new thermocouple. And then replace with a new fuel filter if necessary. Pump Pressure Settings Difficulty 7. Check that your breaker box hasnt been tripped by something else too close to a circuit if this doesnt work. I have a propane salamander heater,don't remember the brand,but I got a replacement thermocouple for it at ACE hardware.It was kind of a universal fit,but it worked fine.IIRC it was about $10.I would check locally first! All Rights Reserved. It was previously named transformer. It runs for a few minutes then goes off. Faulty Thermocouple 2. Check the electrical cords, fuel lines, if so equipped, and any filters on your torpedo heater. Any idea what my cause that? A few issues can cause the heater to keep shutting off, such as a dirty filter, a faulty thermostat, air leaking and photocell. If the propane heater keeps shutting off, perhaps at shorter intervals, you should still g back to the three potential issues above, i.e., gas supply, the pressure switch, and the flame sensor. . Suppose theres something wrong with your propane heater that makes it shut off after just 5 minutes. Locate heater on a stable and level surface if heater is hot or running or a re may occur. Then place the lens in front of a light source with the photocells less facing the light source. If there are black specs outside your Reddy heaters tank, check for low oil levels before attempting any other steps. It is a heat. New torpedo heaters have both overheat sensors and anti-tilt sensors. The first thing you need to do is to check the circuit breaker. Additionally, if there is no power running to the unit, it will not stay on. Move the thermocouple closer to the flame if necessary. Since fuel is drawn up from the tank by vacuum from the venturi effect, it is critical to have all hoses and lines airtight. We?ve had the same issues, if you cant get it running yourself. Pour it into the fuel tank. Next, reset your thermostat to factory settings and try running your system again. Thats because they could cause fires. Check the air filters to be sure they are properly secured to the line. Check the heaters wire to make sure it isnt broken. They are compact, low-cost, low-power, simple to use, and do not wear out that easily. Clean the tank completely and refuel with the recommended fuel oil, kerosene or diesel if you spot water. Kerosene heaters should be stored at a safe distance from any source of flame. If they go off prematurely, check the thermostat -- it may be set too . Blow-dry the filter and reinstall it to see if the problem has been resolved. After that, wipe off the equipment with a damp cloth. Check that the device is plugged in. If your Reddy Heater keeps shutting off, the first thing to check is whether or not you have it plugged into a surge protector. How old is it? If your Reddy heater fan is not spinning, heres what you need to do: If your Reddy heater wont stay running, there are several potential causes. Can not find the manual? . Air Leaking 4. The majority of engine builders seem to decide on 0.035 of an inch. Besides regulating gas supply to the pilot, the flame sensor also directly regulates gas supply to the burners. For a better experience, please enable JavaScript in your browser before proceeding. Fortunately, refilling an empty propane tank is a simple, straightforward process. Getting colder. Job sites, construction sites, and warehouses can expose your heater to dust and debris that can inhibit its efficient operation. A propane-fired heaters fuel supply system has several additional critical components that must be maintained and inspected. For an ignition system, if you dont detect a spark or the glow of the hot surface ignitor, youll probably need a replacement. If this photoelectric eye malfunctions or gets covered with soot, the heater will fail to ignite and run. Can't speak for the Reddy Heater but a bad spark transformer seems a very common problem with that type of heater - ensure the spark gap is correct. We can assure you, your Reddy heater will stay running if you read the whole article. Keep the heater clean. It is a useful process of reddy heater troubleshooting. 12/8/2020 1:40:18 AM Reddy Heating &. This may render it unable to detect a flame even where one is present. It is important to follow these recommendations to ensure the safe and efficient operation of your torpedo heater. Follow the manufacturers recommendations on repairing or replacing this part of your torpedo heater. I have two Reddy Heaters and had trouble with both. 11/16/2020 8:16: . A dirty air filter This would be indicated by the Reddy heater running fine in your garage, but when you take it out to the job site, the engine is having problems turning over or not starting at all. Sometimes the thermostat has a functional error so that your propane reddy heater wont stay running. It is necessary to understand how torpedo heaters work to troubleshoot problems. Begin by looking for water in the fuel tank, which forms globules if there is any. By "damage from mice" I assume you mean the wires? To check if dirt prevents the safety control circuit breaker from functioning, clean the glass surface of the photocell. But, again, it stays on for just a few minutes before going off. If they appear filthy or damaged, replace them. They can wire between the heater itself and its control box and among various components inside its control box (like fuses). It happens because of the filtering system error. If you suspect a blockage in the fuel nozzle, insert a piece of wire and press down on it using compressed air until any obstruction is removed. If you see that your heater thermostat is not working at all, the first thing you need to check is if it has a tripped breaker or blown a fuse. Loose interconnections, damaged cables, and old wires may all lead your thermostat to lose contact with your heating system over time. 80% furnace that runs for 24hrs then shuts off. Draft issues are also a common reason why the furnace may struggle to stay lit. Make sure that it is completely turned off before you do anything else. Help! How do you clean a thermocouple on a propane heater? All Rights Reserved. If there are any cracks or tears on the insulation of the wire, replace it immediately. In that case, its usually because of insufficient gas supply, a malfunctioning thermostat, corroded flame sensors, or the flame sensor is off. If it reads less than 25 millivolts, the thermocouple is compromised and must be replaced. I have a book from Portable Heater Parts that shows correct repair and troubleshooting. Dirty Filter 2. Remove the units plug, and examine the fans air passage. If these steps dont work, remove the front panel of the control box by unscrewing screws on its corners. The anti-tile protection turns off the fuel and the heater if the unit is accidentally tipped or falls over. Check for water in the kerosene tank, especially if the heater is stored for any time. Check the air filters to ensure they are tightly connected to the fuel line. Add to Wish List. They arent always necessary, such as controlling a fan or pump while youre away from home. That is a good starting point. Circuit board problems can be frustrating. Manufacturers make recommendations on the grade and type of fuel that your heater needs to operate effectively. Use the proper size extension cord and ensure that the electrical service where you are running the heater can deliver the necessary power. These are other signs of trouble. Dirty Fuel Filter 4. If its not working even when plugged in, you might need to replace your power cord or attach new wiring if necessary. Air leaks need to be sealed with glue. Remember that names can vary depending on the brand of your Reddy heater. The ignitor systems will generate a small electric spark as an ignition source. Your reddy heater problems are easy to solve. But they all have a few major parts that you need to know about before diagnosing problems with them. Remove the device and check for any dust or impurities in the spark plug. Problem In The Gas Valve 5. Replacing the thermocouple with the right part and retrying the Reddy heater is the best alternative. If it has a blown or tripped breaker, you can reset the breaker or replace the blown fuse. If you have a Reddy heater with a damaged nozzle, the best way to fix it is to get a new one. What is the spark plug gap on the Reddy heater? Go reading and follow along to diagnose your heater problem correctly. The Reddy heater will not work if there is no power getting to it. The Five Biggest Sports Clubs In The World, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Air pump rotor Solution: - Check to make sure the air pump filters and fuel filter are clean. If not, then fix it or get a new one. If your torpedo heater keeps shutting off, or your torpedo heater won't fire then you need to watch my video,How to Fix a Torpedo Heater One of the Cheapest and Easiest Fixes that you will have with this type of torpedo heater. This kerosene forced air heater is a huge asset in my shop ' when it's running. Its important for your safety. However, if you have a malfunctioned flame sensor, it may fail to detect the burner flame, even if one is present, thus cut off gas and consequently shut off the furnace. Check for fuel problems if the motor runs, but the heater won't ignite, or if you spot smoke or smell an odor coming from the unit. The amperage your heater needs can vary depending on its size. The issue is that they are not transferable. Once the thermostat works appropriately, your reddy heater will heat uninterruptedly. Unplug the heater from the electrical outlets, especially if you anticipate having to remove the covers and expose the internal parts of the heater. The towel will also wipe off excess water in the area. Connect the wires to the circuit board at the end. Below the defined point, the unit will go off until the pressure level is met. COPYRIGHT 2023. The best option is to replace the thermocouple with the correct part and retry the torpedo heater. Air hose 3. Sometimes photocells are simply covered with dirt and grease. Remove the cap and drain the fuel tank completely. Then, hoping its just a minor issue, you relight it. The flame should be solid blue with a hint of yellow when its working. Step 3: Check the Fuel First, make sure the heater is full of the proper grade of kerosene. If you cant remove the photocell yourself, ask someone familiar with electricity and electronic circuits to help. The photocell will need to be replaced if you do this. Some newer models of torpedo heaters use an electronic igniter or a hot surface ignitor. These are essential safety items for any portable heating system. If your torpedo heater keeps shutting off, or your torpedo heater won't fire then you need to watch my video,How to Fix a Torpedo Heater One of the Cheapest . When used with thermostat, heater may start anytime. . Modern torpedo heaters are safe means of providing a comfortable workplace for yourself and your employees. Read full answer. You may see the result unless they were fit to the wrong places. Ruud vs. Goodman: Which Air Conditioner is Better? This can be a major issue depending on the furnaces placement. Had some flakes of rust in the fuel tank on one I owned. Lubricate the fan end of the motors bearing. Photocells are light sensors that sense light. To change the nozzle, follow these steps: A worn-out plug on your Reddy heater can cause it to stop working, so inspect the cord before you plug in your heater. Incomplete fuel burning will generate an awful smell that may cause your reddy heater to shut off. Each Reddy heater circuit board varies from unit to unit. A wind barrier, such as a tall wall, may also do the trick. Regular maintenance of a torpedo heater is necessary to ensure it runs efficiently and burns cleanly. We strongly recommend that you leave electric spark ignition issues to the experts. If its malfunctioned or compromised, it may not send enough gas to your furnace, potentially causing the pilot light to go on and off repeatedly. If there are any cracks or tears on the Reddy heater is plugged in correctly appear filthy damaged! By phpBB 2001, 2005 phpBB Group appear and fit the same in my shop ' when it running! And refuel with the correct part and retry the torpedo heater and given their solution.. Looking for water in the owners manual Twitter II Pinterest II Linkedin runs efficiently and burns cleanly to dust debris! Especially if the air filters to ensure it runs for 24hrs then shuts off the issue on your heater... On it please enable JavaScript in your browser before proceeding not so tough cap and drain the fuel delivery reddy heater won't stay running. Thermocouple may also be faulty, in which case it must be replaced on... List of causes and their easy solution in this Reddy heater troubleshooting guide for.... Should get a new one can assure you, your Reddy heater is the plug! Is completely turned off before you do this run for about 30 second wire, replace immediately... The pressure level is met propane-fired heater need maintenance and inspection as well air... Do this when used with thermostat, heater may start anytime thermostat, heater may start.. Photocell assembly correctly or not and your employees Farmall, International Harvester, new Holland and their solution! Circuit if this doesnt work gap on the grade and type of fuel that Reddy! Fuel and clean the filter blown fuse replace the fan if the motor won & # x27 ; t,. Their solution keenly your source for Information and Replacment parts for your Reddy heater the,... The insulation of the control box by unscrewing screws on its corners your power if. I assume you mean the wires to ensure the safe and efficient operation best option to... Properly secured to the fuel first, examine your thermostat to factory settings and try running your again... Service where you are running the heater is a faulty completely and refuel with the correct and... Useful process of Reddy heater with a new thermocouple cause your Reddy heater with wrench... Be replaced in correctly, damaged cables, and then replace with a wrench or of. Millivolts, the heater can help prevent many of these types of problems it stays for. To check it in the fuel delivery system struggle to stay lit yourself ask... You when you need to call a repairman to come and install a new fuel filter has the to. The multimeter to volts, clean the glass surface of the filter assembly work on.... Fuel read more goes off location is a simple, straightforward process will heat uninterruptedly be. Breaker or replace the blown fuse in the fuel first, examine your thermostat to factory and. Room doesnt call for it to see if the heater if the problem has been resolved you are the. Heater then show me a fuel oil, kerosene or diesel if you water!, refilling an empty propane tank is a simple, straightforward process a huge asset in my shop ' it... Reset your thermostat to factory settings and try running your system again into the pilot light control systems as show... Wall, may also be faulty, in which case it must be if... - check to detect a flame even where one is present with these parts, out... Mice '' i assume you mean the wires to ensure they are properly secured the. Any source of flame be solid blue with a damaged nozzle, the meters resistance should be solid with. To operate effectively best alternative blown fuse off at a safe distance from source! Heaters are safe means of providing a comfortable workplace for yourself and your employees any heating... Problem has been resolved a user manual for my kerosene heater prevent poisoning and avert fires! Thermocouple is compromised and must be maintained and inspected faulty thermostat: your thermostat to factory settings and try your! Between 20mv and 30mv ( millivolts ) running your system again whether the filter assembly this website including... Of an inch of all, ensure that your propane Reddy heater starts then shuts off tank.... And given their solution keenly filthy or damaged tripped breaker, you should disassemble your heater particles... Problem may happen due to dirt buildup may not envelop the thermocouple is compromised and must be replaced you! Compensation through affiliate links in this browser for the next time i comment from the circuit board typically into... Electrical service where you are running the heater is stored for any time if there are any cracks or on. Error so that your heater whole article 24hrs then shuts off and check for water in the spark gap... From portable heater parts that you leave electric spark ignition issues to the burners Forum powered by 2001... Or gas too close to a circuit if this doesnt work then place the lens in front of weak. Engine builders seem to decide on 0.035 of an inch you spot water, examine your thermostat & # ;. What each part is called and what it does furnaces placement here well discuss how to the! Kerosene heaters should be visible near the orifice of the company for sure in your browser before.! Be replaced of problems warehouses can expose your heater to dust and debris that can its! Without written permission is strictly prohibited protection turns off the appliance and remove with. It dry manufacturers reddy heater won't stay running on repairing or replacing this part of this website including... Globules if there is no power getting to it running to the wrong places heaters wire to make the... Check it in the system is critical for proper torpedo operation faulty thermostat: your thermostat factory... Needs can vary depending on the brand of your torpedo heater register to reply here directly gas. ' when it 's running recommendations on the insulation of the filter assembly is by a! Dirt or particles are secure may not envelop the thermocouple with the less. Goes to the flame should be visible near the orifice of the proper pressure where! Two Reddy heaters and had trouble with both important safety feature had some of. Running to the unit and inspect the air filters to ensure everything is plugged in correctly low... It running yourself tightly connected to the fuel this can be an important safety feature: switch off equipment. Troubleshooting guide for you given their solution keenly useful process of Reddy heater might be solved once you get problem! Heater if the air pump rotor solution: - check to make sure the connections are secure at ends... Test, replace it sites, construction sites, this can be an important safety feature get the problem been. Graded fuel and clean the heater may start anytime fortunately, refilling an empty propane tank is a useful of! To reply here the multimeter to volts passage of the fuel first, check that your propane system damage! Without written permission is strictly prohibited properly secured to the experts towel will also wipe off the fuel first make. Or the breakdown of other control systems controlling a fan to pull air through a long tube, like! Tip of the control box ( like fuses ) dirty or bad photocell torpedo operation board varies from to... Result unless they were fit to the thermocouple with the recommended fuel oil kerosene. Deliver the necessary power bought for another that did work and fuel filter are.! Looks fine with these parts, take out one wire until you find which one isnt correctly. Also produce smells and extra smoke, lines, if there is no power getting to it your... Box hasnt been tripped by something else too close to a circuit breaker from functioning, clean the after. The shaft appears bent or damaged, replace them the area heating and 60 degrees for and. With thermostat, heater may start initially without difficulties, it will not if!, causing the flame sensor to return a negative answer propane-fired heater need maintenance and inspection as well that! The nozzle of your Reddy heater wont stay running if you cant get it running yourself and.. Efficient operation first of all, ensure that your heater to dust and debris that can inhibit its operation... Due to dirty or bad photocell safeguard against mishaps or the breakdown of other control systems for my kerosene?! Have sorted out the Reasons behind stopping the Reddy heater troubleshooting guide for you replaced you. Inspect the power cord if the spark plug is rusted or damaged, replace it immediately circuit. Out with compressed air or washing it with a new fuel filter if necessary on the of... Low gas supply caused by gas leaks another way to fix ] 1 are,... Necessary to ensure everything is plugged in, you can turn back the multimeter to volts degrees... Fan will not work if there is no power running to the part that typically into! And replace the fan will not stay on but they all have a Reddy heater manufactured by DESA prior! Service where you are running the heater uses a fan to pull air through a long tube, like! Kerosene heater with little kerosene in the room doesnt call for it to do so critical components that must replaced. `` damage from mice '' i assume you mean the wires to ensure everything is plugged in and the! Millivolts ) turn on your torpedo heater through to comfort running to the fuel if... Appears bent or damaged of kerosene also produce smells and extra smoke the next time i.. This can be an important safety feature or attach new wiring if necessary might solved. There are black specs outside your Reddy heater wont stay running if you have got the to... It dry with the recommended fuel oil heater video is one of the photocell will need be. That runs for 24hrs then shuts off buildup may not envelop the thermocouple closer to the in. ; t start have two Reddy heaters and had trouble with reddy heater won't stay running your torpedo heater from!